Test Code LAB895 ABO and Rh Type, Blood
Useful For
Determining the blood type (ABO/Rh) of a patient's red blood cells.
Methodology
Capture solid phase automation and manual blood banking methods
Performing Laboratory
Bozeman Health Laboratory Services
Specimen Requirements
Specimen Type: Whole blood
Container/Tube: Pink top preferred (K2 EDTA), or Purple top (EDTA)
Specimen Volume: 6 mL
Specimen Minimum Volume: 3 mL
Collection Instructions: Do not centrifuge. Forward unprocessed whole blood promptly.
Specimen Rejection: Gel tubes are not acceptable. Specimen must be labeled properly. This test is affected by gross hemolysis.
Note: If specimen being drawn may be used for a possible transfusion, refer to test LAB276 TYPE AND SCREEN for banded specimen collection instructions and blood product transfusion instructions.
Specimen Transport Temperature
Ambient <24 hours/Refrigerated >24 hours
Specimen Stability
Specimen Type | Temperature | Time |
---|---|---|
Whole Blood EDTA | Ambient | 24 hours |
Refrigerated | 10 days |
Reference Values
Type: A, B, O, AB, A2
Rh: Positive or Negative
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
86900-ABO
86901-Rh type