Sign in →

Test Code LAB549 Hepatitis B Core Antibody, IgM

Useful For

  • Diagnosis of acute hepatitis B infection
  • Identifying acute hepatitis B virus (HBV) infection in the serologic window period when hepatitis B surface antigen (HBsAg) and hepatitis B surface antibody (anti-HBs) are negative
  • Differentiation between acute and chronic or past hepatitis B infection in the presence of positive hepatitis B core total antibodies.

Methodology

Electrochemiluminescence Immunoassay (ECLIA)

Performing Laboratory

Bozeman Health Laboratory Services

Specimen Requirements

Specimen Type: Serum or Plasma
Container/Tube: Red top, gold top, or light-green top (lithium heparin)
Specimen Volume: 1 mL
Specimen Minimum Volume: 0.5 mL

Collection Instructions:  Spin down within 2 hours of collection.

Specimen Transport Temperature

Refrigerated

Specimen Stability

Specimen Type Temperature Time
Serum or Plasma Ambient 2 hours
  Refrigerated 7 days
  Frozen 3 months

Reference Values

Result Interpretation
< 0.9 COI Non-Reactive

≥ 0.9 to < 1.1 COI

(tested in duplicate)

Equivocal:  Redraw specimen in two weeks and retest

≥ 1.1 COI Reactive

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

86705