Test Code LAB338 Syphilis Confirmation: VDRL with TP-PA
Useful For
Confirming reactive Syphilis IgG and IgM antibody screens
Profile Information
Test Component | Methodology |
Available Separately |
Always Performed |
---|---|---|---|
VDRL (qualitative) | Microscopic Flocculation/Agglutination | No | Yes |
Testing Algorithm:
- If the VDRL screen is positive, a quantitative VDRL titer will be performed, at an additional charge.
- TP-PA testing will be performed on all serum VDRL specimens with results of reactive 2 dilutions or greater, at an additional charge. Initial results of Weakly Reactive or Reactive 1 dilutions should have a second specimen submitted.
Reflex Tests
Test Component | Methodology |
Available Separately |
Always Performed |
---|---|---|---|
VDRL titer (quantitiative) | Microscopic Flocculation/Agglutination | No | No |
TP-PA | Treponema Pallidum AB, Particle Agglutination (TP-PA) | No | No |
Performing Laboratory
Montana State Public Health Laboratory
Specimen Requirements
Specimen Type: Serum
Container/Tube: Red top or gold top
Specimen Volume: 2 mL
Collection Instructions:
- Send 2 mL serum refrigerated.
- If initial testing has been performed and this test is being used for confirmation, fill out and attach the confirmation testing form found below.
Specimen Transport Temperature
Refrigerated
Specimen Stability
Specimen Type | Temperature | Time |
---|---|---|
Serum | Ambient | 8 hours |
Refrigerated | 1 week |
Reference Values
Nonreactive
Significant results are telephoned to the submitter.
Day(s) Test Set Up
Monday through Friday
Turnaround Time: Routinely batch tested twice per week.
Test Classification and CPT Coding
86592-Qualitative VDRL
86593-Quantitative VDRL (if indicated)
86780-TP-PA (if indicated)