Test Code LAB1209 Q Fever IgM and IgG, Titer, Serum

Additional Codes

Mayo Test Code: QFP

Useful For

Diagnosis of Coxiella burnetii, the causative agent of Q fever

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


 



Specimen Required


Only orderable as a reflex. For more information see QFEVR / Q Fever Antibody Screen with Titer Reflex, Serum.

 

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 7 days
  Frozen  7 days

Reference Values

Only orderable as a reflex. For more information see QFEVR / Q Fever Antibody Screen with Titer Reflex, Serum.

 

Q fever phase I antibody, IgG

<1:16

 

Q fever phase II antibody, IgG

<1:16

 

Q fever phase I antibody, IgM

<1:16

 

Q fever phase II antibody, IgM

<1:16

 

Reference values apply to all ages.

Day(s) Performed

Monday through Saturday

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86638 x 4

Report Available

Same day/1 to 3 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Method Name

Only orderable as a reflex. For more information see QFEVR / Q Fever Antibody Screen with Titer Reflex, Serum.

 

Indirect Immunofluorescence